Oonagalabi Drilling Strengthens Geological & Targeting Model
Released
Released
Announcement PDF
1 | P a g e
3rd
June 2026
Oonagalabi Drilling Strengthens Geological and Targeting Models
with thick copper-zinc mineralisation continuing
Highlights
• Completed 11 RC holes for 1,772m and three diamond holes for 1,217.9m (including an 81.5m RC pre-collar in
hole OGRD001).
• Broad to narrow zones of copper and zinc mineralisation were encountered in the Main Zone.
Drilling highlights include:
o Combined OGDD002 intercept of 68.26m at 0.62% Cu, 1.44% Zn and 4.3 g/t Ag from 10m;
o Combined OGRC029 intercept of 120m at 0.35% Cu, 0.92% Zn, and 4.1g/t Ag from 52m; and
o OGRC028 intercept of 39m at 0.69% Cu, 1.14% Zn and 5.3g/t Ag
o Combined OGRC022 intercept of 50m at 0.47% Cu, 1.36% Zn and 4.2g/t Ag from 2m.
• Minor copper sulphides were intersected at VT1 in the metamafic zone, suggesting new style of mineralisation.
• At Bomb Diggity, hole OGRD001 intersected a molybdenite-iron sulphide-quartz-carbonate vein containing
either a hydrothermal nickel sulphide or a nickeliferous iron-sulphide mineral. These sulphides may support a
long-lived multi-event mineralisation model for the region.
• The drilling results enable refinement of regional and local targeting models, improving the correlation between
geophysical responses and mineralisation, while enhancing understanding of target geometry and structural
controls.
• Assay results for the mineralised zone in hole OGDD003 remain pending from the laboratory.
Litchfield Minerals Limited (“Litchfield” or “the Company”) (ASX:LMS) is pleased to report assay results from Phase 3 RC
and diamond drilling at the Oonagalabi Project.
Managing Directors Comments
"This drilling campaign was one of those programs that challenged the team at every turn. From significant weather
disruptions and access issues through to personnel changes and the complexities of drilling a highly deformed mineral
system, not everything went to plan. Despite this, the campaign has improved our understanding of the Oonagalabi
mineral system and generated several important vectors for future exploration.
The Oonagalabi Main Zone continues to return broad copper-zinc mineralisation; however, the geometry of the system
appears more structurally complex than initially modelled. The next phase of work will focus on integrating drilling,
geophysics and structural interpretations to better constrain the mineralised system and improve drill targeting. The
objective is to position future drilling more precisely within the key structural corridors believed to control the highest-
grade and thickest zones of mineralisation.
At Bomb Diggity, the magnetic anomaly remains unresolved. While drilling intersected sulphides and an unusual nickel-
molybdenum-bearing quartz vein, neither the geology nor the assay results adequately explain the strength of the
magnetic response. The anomaly remains open and requires further work to better constrain its source. Importantly,
the identification of nickel and molybdenum together within a hydrothermal vein is unusual and supports the possibility
of multiple mineralising events occurring across the district.
2 | P a g e
Looking ahead, we are particularly excited by the next phase of regional and local work. Through the BHP Xplor program,
the Company is planning two 50km, 1km-spaced north-south Magnetotelluric (MT) survey lines (pending approval)
across the interpreted Aileron-Irindina Province boundary. Publicly available MT data, collected at 10km spacing, already
suggests conductivity anomalies beneath and west of Oonagalabi, and the higher-resolution surveys are designed to test
whether these features represent deeper crustal pathways or source regions capable of driving large-scale mineral
systems.
While this drilling campaign generated as many questions as answers, each result has contributed to a better
understanding of the geological system. Collectively, these datasets are helping us build and refine the geological model,
which we believe is critical to unlocking the full potential of the Oonagalabi region. The combination of broad base metal
mineralisation, multiple mineralisation styles, unresolved geophysical anomalies and emerging regional-scale targets
continues to support our belief that Oonagalabi remains a highly compelling exploration opportunity”.
Drilling Highlights
A total of 11 RC holes (1,772m) and 3 diamond holes 1,217.9m) (including an 81.5m RC pre-collar in hole OGRD001)
were completed across the Bomb-Diggity, VT1, VT2 and Main Zone targets on EL32279 (Figure 1 and Appendix 1).
Further Thick Copper-Zinc Mineralisation at Oonagalabi identified
Drilling confirmed broad to narrow zones of copper–zinc mineralisation, including multiple high-grade internal zones.
Several drill holes intersected a broad, stacked mineralised package from near surface, confirming both lateral and
vertical continuity of mineralisation within the Oonagalabi Main Zone. Assay results for the mineralised zone of hole
OGDD003 are still pending from the laboratory.
The Cu, Zn and Ag results included the following combined intercepts:
• Combined OGDD002 intercept of 68.26m at 0.62% Cu, 1.44% Zn and 4.3g/t Ag from 10m, including intervals of:
o 19.66m at 0.66% Cu, 2.58% Zn and 5.6g/t Ag from 10.00m;
o 14.00m at 0.52% Cu, 1.55% Zn and 6.1g/t Ag from 36.00m;
o 19.01m at 1.06% Cu, 0.7% Zn and 5.0g/t Ag from 143.14m;
o 6.29m at 0.37% Cu, 2.05% Zn and 2.3g/t Ag from 171.51m; and
o 8.02m at 0.09% Cu, 0.48% Zn and 0.8g/t Ag from 183.85m.
• Combined OGRC029 intercept of 120m at 0.92% Zn, 0.35% Cu and 4.1g/t Ag from 52m, including intervals of:
o 60m at 0.52% Cu, 1.26% Zn and 6.3g/t Ag from 52m;
o 15m at 0.20% Cu, 0.98% Zn and 2.1g/t Ag from 122m;
o 45m at 0.21% Cu, 0.51% Zn and 2.0g/t Ag from 147m, including:
▪ 11m at 0.98% Zn and 3.8g/t Ag from 157m, with the 45m zone including intervals of 16m at
0.32% Cu from 158m, and 3m at 0.32% Cu from 177m, and 7m at 0.31% Cu from 184m.
• Combined OGRC022 intercept of 50m at 0.47% Cu, 1.36% Zn and 4.2g/t Ag from 2m., including:
o 37m at 0.53% Cu, 1.54% Zn and 4.9g/t Ag from 2m;
o 8m at 0.23% Cu, 0.57% Zn and 2.9g/t Ag from 67m; and
o 5m at 0.19% Cu and 0.32% Zn from 87m.
Other drilling results included:
• OGRC028 intercepts of 39m at 0.69% Cu, 1.14% Zn and 5.3g/t Ag from 60m, and 2m at 0.24% Cu, 3.78% Zn and
2.2g/t Ag from 14m;
• OGRC031 intercepts of 21m at 0.38% Cu, 1.85% Zn and 4.1g/t Ag from 18m, 19m at 0.39% Cu, 1.58% Zn and
5.9g/t Ag from 55m, and 12m at 0.14% Cu, 0.76% Zn and 1.1g/t Ag from 86m; and
• OGRC023 intercepts of 20m at 0.27% Cu, 0.82% Zn and 1.9g/t Ag from 0m, 8m at 0.13% Cu from 36m, and 4m
at 0.19% Cu from 108m.
3 | P a g e
Figure 1. Map of the 14 RC and diamond drill collars from Phase 3 drill program on EL32279.
OGDD002 – 300.1 m Diamond hole (Oonagalabi Main Zone)
Along with the assay results reported above, this drill hole, which the NT Government GDC Round 18 co-funded, was
designed to improve understanding of local and regional mineralisation potential. Given the lack of historical diamond
core available, new core was drilled to clearly define ore textures and cross-cutting relationships of mineralisation to
host rocks and structures.
As observed, zones of chalcopyrite and sphalerite mineralisation (Figure 2) appear younger and crosscut the main
foliation fabric in gneiss, although it is unclear whether the sulphides (and/or their calc-silicate host) have been
subsequently deformed. Petrology work is planned in order to understand the relative timing of this mineralisation.
4 | P a g e
Figure 2. Diamond drill core from 158m downhole depth in OGDD002 assaying 1m at 3.1% Cu and 0.9% Zn.
Bomb-Diggity Target and Magnetic Finger at Oonagalabi
Magnetic targets at Bomb Diggity and in the Oonagalabi Main Zone were also tested by diamond drilling, which was co-
funded by the NT Government GDC Round 18 program (Figure 3). Currently, there are no clear geological explanations
for the interpreted magnetic anomalies targeted in holes OGRD001 (Bomb Diggity) and OGDD003 (magnetic finger at
Oonagalabi). Hole OGRC021 at Bomb Diggity also intercepted a modelled magnetic zone, however, no evidence for the
modelled magnetic zone was determined in that hole as discussed below.
While the source of these magnetic anomalies remains unresolved, the anomalies themselves continue to represent
exploration targets. The inability of the current drilling program to fully explain these magnetic responses highlights that
important components of the geological model remain unconstrained and requires further investigation. The Company
will now integrate the new drilling data into updated geophysical models and work closely with its geophysical
consultants to refine the interpretation of these anomalies. This process is expected to improve understanding of the
target geometry and assist in determining the source of the magnetic response. Magnetic susceptibility measurements
were collected at 1m intervals down drill core or from the RC drilling 1m interval samples (Appendix 4). The
measurements did not yield any strongly anomalous results in these holes other than minor magnetite veining (≤ 20cm
width). In hole OGRD001, minor iron sulphides in ≤ 4m wide zones were intersected, however, these do not explain the
5 | P a g e
interpreted anomaly. At OGDD003, copper-zinc mineralisation was logged, with assays pending, however, there are
currently no mineralogical explanations for the interpreted magnetic anomaly tested.
It is possible that the magnetic anomalies represent discrete intrusions that were not intersected during the drilling, or
that they may more broadly represent numerous metamafic intrusions and sills found within the host succession at
Oonagalabi. The Company notes that with a better constrained model, relatively small changes in drill position or target
geometry can result in significant differences in geological outcomes when testing discrete magnetic bodies at depth.
Integration of the new drilling data with detailed geophysical modelling is expected to significantly improve future
targeting accuracy.
Figure 3. Cross section showing holes OGRD001 & OGRC021 (black lines) at Bomb Diggity piercing the targeted magnetic anomalies (brown shells).
Unusual hydrothermal molybdenite-iron sulphide-nickel-bearing sulphides in quartz vein
One of the most significant geological observations from the current drilling campaign was the identification of a
hydrothermal molybdenite-bearing quartz-carbonate vein containing nickel-bearing sulphides at Bomb Diggity at
617.2m depth. This vein (Figure 4) contains molybdenite, iron sulphides (pyrrhotite and/or pyrite) and an unconfirmed
mineral that is likely to be either a Ni-bearing sulphide (like pentlandite) or nickeliferous pyrite or pyrrhotite. The quartz
vein crosscuts the main foliation fabric in the host gneiss. The 617-619m assay interval that incorporates this 10cm vein
returned 626ppm Mo, 206ppm Ni and 7150ppm S, which supports the following interpretation (Appendix 5). The
interval was sampled as a two-metre composite, meaning the nickel-bearing sulphide occurs within a narrow
approximately 10cm vein and its grade has been diluted across the full two-metre assay interval.
The initial interpretation is that the association of nickel and molybdenum within a hydrothermal vein system is
considered unusual and may indicate a previously unrecognised mineralising event within the Oonagalabi region. Such
associations can provide important insights into fluid chemistry, metal sources and mobility and regional mineral
systems. To assist, molybdenite from the vein has been sent for Re-Os chronology. The unusual Ni-bearing sulphide
6 | P a g e
mineral will also be confirmed using additional analytical methods. Confirmation of younger hydrothermal nickel and
molybdenum mineralisation would support emerging interpretation of a multi-phase mineralising system at Oonagalabi.
Figure 4. 617.2m depth in OGRD001 showing 10cm quartz vein with molybdenite-iron sulphide and an unconfirmed nickel-bearing sulphide
mineral. Drill core is 5cm wide. The quartz vein crosscuts the main foliation fabric in the host gneiss.
VT1 Target – Sulphides Intersected, Target Remains Open
Hole OGRC026 aimed to tested two 200 siemens plates and an IP chargeability anomaly adjacent to outcropping gossan
zones. Previous drilling of other conductor plates in the VT1 target area yielded trace disseminated pyrrhotite-
chalcopyrite-sphalerite-pyrite in hole OGRC012, although this drilling missed the intersection of the main EM plate1
.
Hole OGRC026 intersected felsic gneiss and lesser metamafic rocks. This 120m deep hole merely clipped the top of both
plates being tested (Figure 5). Nonetheless, logged trace pyrite and pyrrhotite and corresponding higher S, Fe and Cu
concentrations in assay intervals correlate reasonably well with the pierce points of the EM plates.
1
ASX Announcement – 12/01/2026 - Ground EM Defines 3000-Siemens Conductor 1km Carbonate Unit at VT1
7 | P a g e
Figure 5. Plan view of drilling of hole OGRC026 showing hole trace (faint blue line) and intersection of 2 modelled EM plates (purple
and grey).
Hole OGRC027 tested a modelled 3,000 siemens EM conductor plate (Figure 6). It intersected disseminated pyrrhotite,
pyrite and minor chalcopyrite within metamafic and felsic gneiss. The best assay results returned 2m at 0.16% Cu from
27m, with elevated sulphur and iron values broadly coinciding with the interpreted conductor position.
While the presence of sulphides is encouraging, a 2m finely disseminated intersection of 0.16% Cu of mineralisation
from 27m is insufficient to explain a conductor of this magnitude. A 3,000 siemens response typically requires a
substantially larger volume of conductive material than that observed in the drill hole. As a result, the source of the
conductor remains unresolved.
Importantly, the copper and iron sulphides at VT1 have a different host rock (metamafic) and different sulphide
assemblage (lacking sphalerite) compared to the main Oonagalabi prospect nearby. This observation may support a
different style of mineralisation and multiple regional mineralising episodes.
Confidence in the modelled conductor remains high. Due to limited drill rig availability during the campaign window,
the Company was required to utilise a contractor that did not have access to some of the high-precision drill positioning
and GPS mast surveying equipment typically preferred for testing discrete geophysical targets. This constraint, combined
with pad positioning limitations in the field, may have contributed to the drill hole testing the margin of the modelled
conductor rather than its interpreted core.
8 | P a g e
Figure 6. Plan view of drilling at OGRC027 showing the drill hole trace (blue line) intersecting the top of the modelled EM plate (yellow polygon).
VT2 Target – Limited Mineralisation, Further Assessment Ongoing
Two holes were drilled at VT2, targeting the northern extent of the VT2 electromagnetic conductor (hole OGRC024) and
an IP chargeability anomaly (hole OGRC025). Previous drilling in holes OGRC011 and OGRC019 targeting EM plates
intercepted minor copper-zinc-iron sulphide mineralisation (for example OGRC011 intercepted a main zone of 5m at
0.3% Cu and 1.5% Zn from 246m2
). Neither of the new drill holes intersected significant Cu nor Zn mineralisation. Hole
OGRC024 aimed to test a low conductivity target (80 siemens plate) along strike from hole OGRC019. Hole OGRC024
intersected felsic gneiss and lesser metamafic rocks. No sulphides were logged despite piercing the centre of the
modelled EM plate (Figure 7). Hole OGRC025 tested the strongest part of the VT2 IP chargeability anomaly, however,
only very trace levels of pyrite were logged that were associated with quartz-sericite veins within metamafic rock.
2
ASX Announcement – 5/02/2026 - Further Thick CopperZinc Mineralisation at Oonagalabi
9 | P a g e
Figure 7. Plan view of drilling of OGRC024 and OGRC025 (blue lines show hole traces) and modelled EM plates (various polygon colours). Note
that OGRC025 tested an IP chargeability anomaly so is not associated with an EM plate model.
Next Steps
The current drilling campaign has advanced the Company's understanding of both the local Oonagalabi mineral system
and the broader regional geological framework. Importantly, several results from this program continue to support the
Company's emerging view that Oonagalabi may form part of a much larger mineral system associated with the
interpreted Aileron-Irindina Province boundary.
To further test this concept, in conjunction with the BHP Xplor program, Litchfield is progressing plans for two regional
north-south Magnetotelluric (MT) lines, each approximately 50km long at 1km reading spacings, across granted and
application tenure within the Harts Range region. These surveys are specifically designed to determine whether large-
scale conductive bodies exist beneath Oonagalabi and adjacent parts of the belt.
The Company is particularly encouraged by publicly available AUSLAMP MT data, which indicates a conductivity anomaly
beneath and immediately west of Oonagalabi. The planned higher-resolution MT survey will provide an opportunity to
test these features in significantly greater detail and assess whether they may represent deep crustal pathways or source
regions capable of driving large-scale mineral systems.
10 | P a g e
Future work includes:
• Integration of assays, petrology and geophysics to refine 3D targeting models. Planning of next drilling campaign
will focus on high-confidence, constrained targets;
• Petrology work is planned to understand the timing and nature of mineralisation at Oonagalabi;
• Re—Os molybdenite chronology and petrology is already underway on unusual molybdenite-Ni-bearing
sulphide quartz vein at Bomb Diggity;
• Magnetotelluric and ground gravity surveys planned to be undertaken across EL32779 Oonagalabi tenement in
conjunction with the BHP Xplor program;
• Induced Polarisation (IP) survey at Silver Valley to identify potential sulphide-bearing extensions at depth to the
high-grade silver-bearing quartz vein system found at surface and generate drill-ready targets; with fieldwork
already underway at the Silver Valley Project in the Davenport Ranges and the Brumby Bore area in the Irindina
Province;
• Drill testing the Mount Irene copper prospect within the Mount Doreen Project, targeting a large chargeability
anomaly identified through previous geophysical surveys; and
• Further drilling at Oonagalabi following the integration of recent drilling, geophysical and geological datasets,
with the aim of refining target definition and improving drill targeting across the broader mineral system.
Cautionary Statement
This announcement contains forward-looking statements that involve known and unknown risks, uncertainties, and
other factors that may cause actual results, performance, or achievements to differ materially from those expressed or
implied. Such statements include but are not limited to, interpretations of geophysical data, planned exploration
activities, and potential mineralisation outcomes. Visual estimates of mineral abundance and pXRF results should never
be considered a proxy or substitute for laboratory analyses where concentrations of grades are the factors of principal
economic interest. Visual estimates also potentially provide no information regarding impurities or deleterious physical
properties relevant to valuation. Forward-looking statements are based on Litchfield Minerals Limited’s current
expectations, beliefs, and assumptions, which are subject to change in light of new information, future events, and
market conditions. While the Company believes that such expectations and assumptions are reasonable, they are
inherently subject to business, geological, regulatory, and operational risks. Further work, including drilling, is required
to determine the economic significance of any anomalies identified. Investors should not place undue reliance on
forward-looking statements. Litchfield Minerals Limited disclaims any obligation to update or revise any forward-looking
statements to reflect events or circumstances after the date of this announcement, except as required by law.
About Litchfield Minerals
Litchfield Minerals is a critical mineral explorer, primarily searching for base metals and uranium out of the Northern
Territory of Australia. Our mission is to be a pioneering copper exploration company committed to delivering cost-
effective, innovative and sustainable exploration solutions. We aim to unlock the full potential of copper and other
mineral resources while minimising environmental impact, ensuring the longevity and affordability of this essential metal
for future generations. We are dedicated to involving cutting-edge technology, responsible practices and stakeholder
collaboration drives us to continuously redefine the industry standards and deliver value to our investors, communities
and the world.
11 | P a g e
Competent Person’s Statement
The information in this announcement relates to Exploration Results and is based on, and fairly represents, information
and supporting documentation compiled by Dr Matthew McGloin (PhD, MGeol), a Competent Person who is a Member
of the Australian Institute of Mining and Metallurgy (AUSIMM) and is a full-time employee of Litchfield Minerals Limited.
Dr. McGloin has sufficient sampling experience that is relevant to the style of mineralisation and types of deposits under
consideration and to the activity being undertaken to qualify as a Competent Person as defined in the 2012 Edition of
the “Australasian Code for Reporting of Exploration Results, Mineral Resources and Ore Reserves” (JORC Code). Dr.
McGloin consents to the inclusion in the Public Report of the matters based on their information in the form and context
in which it appears. With regard to the Company’s ASX Announcements referenced in the above Announcement, the
Company is not aware of any new information or data that materially affects the information included in the
Announcements.
The announcement has been approved by the Board of Directors. For further information please contact:
Matthew Pustahya- Managing Director
Matthew@litchfieldminerals.com.au
Phone 0451 976 285
Follow us on:
www.litchfieldminerals.com.au
https://twitter.com/Litchfield_LMS
https://www.linkedin.com/company/litchfield-minerals-limited/
JORC Code, 2012 Edition – Table 1 Report - Section 1 - Sampling Techniques and Data
Criteria JORC Code explanation Commentary
Sampling techniques • Nature and quality of sampling (e.g. cut channels, random
chips, or specific specialised industry standard
measurement tools appropriate to the minerals under
investigation, such as down hole gamma sondes, or
handheld XRF instruments, etc). These examples should
not be taken as limiting the broad meaning of sampling.
• Include reference to measures taken to ensure sample
representivity and the appropriate calibration of any
measurement tools or systems used.
• Aspects of the determination of mineralisation that are
Material to the Public Report.
• In cases where ‘industry standard’ work has been done
this would be relatively simple (e.g. ‘reverse circulation
drilling was used to obtain 1 m samples from which 3 kg
was pulverised to produce a 30 g charge for fire assay’). In
other cases more explanation may be required, such as
where there is coarse gold that has inherent sampling
problems. Unusual commodities or mineralisation types
(e.g. submarine nodules) may warrant disclosure of
detailed information.
• Reverse Circulation (RC) drilling was used to obtain samples. Samples were collected as
regular metre interval composites, deposited from the cyclone. Drill spoils were deposited
into green plastic bags on the ground adjacent to the drillhole. A smaller calico 1m split
sample was collected for each metre drilled. Samples were collected by scooping from each
individual pile. 4m composite samples were collected for all intervals that did not appear
mineralised after geological logging. Chip samples were collected using a sieve for each
metre drilled and retained in a plastic chip tray that were used to complete geological logging
and mineralisation visual estimates.
• Diamond drill samples were cut as ½ core using a diamond saw. ½ core was then sampled at
specific intervals to account for mineralisation and lithology (typically 0.3m to 1m intervals).
Drilling intervals selected for sampling were decided on a subjective basis by the person(s)
responsible for supervision of the drilling campaign.
• Given the nature of the minerals being sampled, scoop and core sampling are considered by
the Competent Person to be an appropriate method of sampling.
• All ½ diamond core in the entire hole OGRD001 and in the intervals 0.25-265m in OGDD002
and 40-65m in OGDD003 were sampled. Mineralised intervals and some host rocks from RC
holes were sampled as approximately 1kg of each RC chip interval.
• Samples were submitted to the Bureau Veritas Adelaide laboratory for analysis. All samples
were pulverised. QAQC standards (blank, reference and lab duplicates) were included
routinely. Internal Litchfield standards were not inserted for some holes with laboratory
standards used instead. All samples were analysed by conventional multi-element and fire
assay analysis (see Quality of Assay Data section below for further details).
• Reported intercepts were calculated using a cut-off for Cu and Zn of 0.1%. There was no cut-
off for Ag within these Cu and Zn cut-off zones. Diamond core internal dilution was ≤ 2.28m
for Cu and ≤ 0.6m for Zn but typically ≤ 1m. RC internal dilution was ≤ 6m for Cu and ≤ 1m
dilution for Zn but typically ≤ 1m.
Drilling techniques • Drill type (e.g. core, reverse circulation, open-hole
hammer, rotary air blast, auger, Bangka, sonic, etc) and
details (e.g. core diameter, triple or standard tube, depth of
diamond tails, face-sampling bit or other type, whether
core is oriented and if so, by what method, etc).
• All diamond drill holes were completed by DDH1 Drilling using a Sandvik DE840 Multipurpose
rig. Drill core was either HQ or NQ size. All Reverse Circulation holes were completed by
Geodrill using a Schramm 685 rig. Hole OGRD001 had a RC pre collar (OGRC001) of 81.5m
included in the total OGRD001 diamond hole metreage reported.
Drill sample recovery • Method of recording and assessing core and chip sample
recoveries and results assessed.
• Samples were collected and logged at metre intervals (in some cases less for diamond drill
core)
Criteria JORC Code explanation Commentary
• Measures taken to maximise sample recovery and ensure
representative nature of the samples.
• Whether a relationship exists between sample recovery and
grade and whether sample bias may have occurred due to
preferential loss/gain of fine/coarse material.
• RC sample recoveries were visually estimated for each metre with poor or wet samples
recorded in drill and sample log sheets. The sample cyclone was routinely cleaned at the end
of each drill rod and when deemed necessary.
• No relationship has been determined between sample recoveries and grade and there is
insufficient data to determine if there is a sample bias.
Logging • Whether core and chip samples have been geologically and
geotechnically logged to a level of detail to support
appropriate Mineral Resource estimation, mining studies
and metallurgical studies.
• Whether logging is qualitative or quantitative in nature. Core
(or costean, channel, etc) photography.
• The total length and percentage of the relevant intersections
logged.
• Geological logging of RC and diamond drill holes was done on a visual basis with logging
• including lithology, alteration, mineralisation, structure, weathering, oxidation, magnetic
susceptibility etc.
• Logging of RC drill samples is qualitative and based on the presentation of representative drill
chips retained for all 1m sample intervals in the chip trays.
• All drillholes were geologically logged in their entirety.
• A portable XRF instrument (Niton) was used to qualitatively facilitate identification of
mineralised intervals where visual mineralisation was difficult to identify.
Sub-sampling techniques
and sample preparation
• If core, whether cut or sawn and whether quarter, half or all
core taken.
• If non-core, whether riffled, tube sampled, rotary split, etc and
whether sampled wet or dry.
• For all sample types, the nature, quality and appropriateness
of the sample preparation technique.
• Quality control procedures adopted for all sub-sampling
stages to maximise representivity of samples.
• Measures taken to ensure that the sampling is representative
of the in situ material collected, including for instance results
for field duplicate/second-half sampling.
• Whether sample sizes are appropriate to the grain size of the
material being sampled.
• 1m cone split samples were collected for all RC metres at the time of drilling from the drill rig
mounted cone splitter.
• The sample size is considered appropriate for the mineralisation style, application and
analytical techniques used.
• Individual diamond ½ core sampling varied in intervals, with 1m intervals typical, but the
minimum interval being 0.2m.
Quality of assay data and
laboratory tests
• The nature, quality and appropriateness of the assaying and
laboratory procedures used and whether the technique is
considered partial or total.
• For geophysical tools, spectrometers, handheld XRF
instruments, etc, the parameters used in determining the
analysis including instrument make and model, reading times,
calibrations factors applied and their derivation, etc.
• Nature of quality control procedures adopted (e.g. standards,
blanks, duplicates, external laboratory checks) and whether
acceptable levels of accuracy (i.e. lack of bias) and precision
have been established.
• RC Chip and Diamond core samples were analysed using Bureau Veritas me
Share your feedback
Discover